Best Flex Duct For Attic

Get free shipping on qualified best rated flexible ductwork or buy online pick up in store today in the heating venting cooling department.
Best flex duct for attic. They are also used to install ductwork which is not flexible to a certain air supply outlet. Another biggie that i see all the time is sagging ducts. The straps that hold up the flex duct need to be no less than 1 5. Flexible ductwork uses cheaper materials and therefore is a cheaper option.
This means that fully extending the flex is a big deal and may be one of the most overlooked aspects of flex system installations. 4 rules for flexible ducts that remodelers need to know. The fiberglass duct board is by far the most effective. The official recommendation from the adc is that flex ducts should sag no more than 1 2 per foot of length between supports.
The rigid insulation was saturated from condensation. You can find formaldehyde free insulation that also has an acrylic coating. Raise the webbing until the bottom of the flex duct sits 1 2 to 1 inch off the bottom of the attic floor. This type of ducting is best in tricky spaces where rigid ducts are just not possible to install or used to attach non flexible ductwork to an air supply outlet.
All ducts should be sealed using ul 181 rated duct mastic 1 and flexible ducts should be held in place with. Use only what you need. This coating will help to keep the glass fibers from your airstream and excess noise from your home. Seal the ducts with mastic.
The prior owner just had a new ac system installed in which they switched from the equipment and metal ducts in the crawlspace to flex ductwork equipment in the attic where temps have regularly been in the 130 150 degrees this summer. Set your store to see local availability. Pull the webbing back toward the joist to form a loop. The air duct council states that 30 of compression can result in 4 times the air resistance.
Insulated flexible duct with metalized jacket r8 model fd 12r8 09 56 21 56 21. Slide the webbing under the flex duct. The more compressed the duct is when it s installed the greater the air resistance of the duct will be. I found instead a vintage 3 ton ac unit with 1 rigid insulation taped all over it and insulated flex duct snaking all over the poorly insulated attic.
Kinks bends and turns need to be minimized in installation as these issues reduce air flow and could hamper the efficiency and effectiveness of the air conditioner. Using this kind of ducting is best in tricky spaces where rigid ducts are not just possible to install. The supports need to be at the manufacturer s recommended spacing but no longer than 4 maximum.